Product Data Allegiance 16 Models 4a7a6024 036 048 And -Books Download

Product Data Allegiance 16 Models 4A7A6024 036 048 and
03 Apr 2020 | 8 views | 0 downloads | 12 Pages | 1.48 MB

Share Pdf : Product Data Allegiance 16 Models 4a7a6024 036 048 And

Download and Preview : Product Data Allegiance 16 Models 4a7a6024 036 048 And


Report CopyRight/DMCA Form For : Product Data Allegiance 16 Models 4a7a6024 036 048 And



Transcription

Features and,DURATION 2 stage scroll Liquid line filter drier. compressor Low sound with advanced variable,Efficiency up to 18 0 SEER speed fan motor. All Aluminum SPINE FIN coil Service valve cover,DURATUFF weather proof and R 410A refrigerant. rust proof base From 70 to 100 capacity,COMFORT R mode approved modulation. for better comfort indoors 100 run test in the factory. QUICK SESS cabinet Low ambient cooling to 55 as,service access and refrigerant shipped.
connections with full coil,protection Extended warranties available. WEATHERGUARD fasteners,Glossy corrosion resistant finish. tarpaulin gray cabinet with,anthracite gray top,Internal compressor high low. pressure temperature protection, 2013 American Standard Heating Air Conditioning 2 12 1200 14. Features and Benefits 2,General Data 4,Product Specifications 4.
A weighted Sound Power Level dB A 4,Accessory Description and Usage 5. AHRI Standard Capacity Rating Conditions 5,Model Nomenclature 6. Electrical Data 7,Dimensions 8,Mechanical Specifications 9. 12 1200 14 3,Product Specifications, Model No 1 4A7A6024E1 4A7A6036E1 4A7A6048E1 4A7A6060E1. Electrical Data V Ph Hz 2 230 1 60 230 1 60 230 1 60 230 1 60. Min Cir Ampacity 18 24 28 41,Max Fuse Size Amps 20 35 45 60.
Compressor DURATION SCROLL DURATION SCROLL DURATION SCROLL DURATION SCROLL. RL AMPS LR AMPS 13 52 17 82 21 2 104 32 1 152 9,Outdoor Fan FL Amps 0 74 0 74 1 00 2 80. Fan HP 1 8 1 8 1 5 1 3,Fan Dia inches 27 6 27 6 27 6 27 6. Coil Spine Fin Spine Fin Spine Fin Spine Fin, Refrigerant R 410A 9 13 LB OZ 9 13 LB OZ 12 9 LB OZ 12 9 LB OZ. Line Size in O D Gas 3 5 8 3 4 7 8 1 1 8,Line Size in O D Liquid 3 3 8 3 8 3 8 3 8. Dimensions H x W x D Crated 46 4 x 35 1 x 38 7 51 x 35 1 x 38 7 51 x 35 1 x 38 7 51 x 35 1 x 38 7. Weight Shipping 276 283 308 312,Weight Net 240 245 271 275.
Start Components NO NO NO NO,Sound Enclosure NO NO NO NO. Compressor Sump Heat NO NO NO NO,Optional Accessories 4. Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101. Snow Leg Base Cap 4 High BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002. Snow Leg 4 Extension BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003. Hard Start Kit Scroll BAYKSKT260 BAYKSKT260 BAYKSKT260 BAYKSKT260. Crankcase Heater Kit BAYCCHT301 BAYCCHT301 BAYCCHT301 BAYCCHT301. Extreme Condition Mounting Kit BAYECMT023 BAYECMT004 BAYECMT004 BAYECMT004. Auto Charge Solenoid Kit BAYCAKT001 BAYCAKT001 BAYCAKT001 BAYCAKT001. Refrigerant Lineset 5 TAYREFLN6 TAYREFLN7 TAYREFLN3 TAYREFLN4. 1 Certified in accordance with the Air Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210 240. 2 Calculated in accordance with N E C Only use HACR circuit breakers or fuses. 3 Standard line lengths 60 Standard lift 25 Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub 32 3312 0 denotes latest revision. 4 For accessory description and usage see page 5,5 15 20 25 30 40 and 50 foot lineset available. A weighted Sound Power Level dB A, SOUND POWER A WEIGHTED FULL OCTAVE SOUND POWER LEVEL dB dB A. LEVEL dB A,63 125 250 500 1000 2000 4000 8000, 4A7A6024G 72 43 7 52 6 54 3 62 4 60 4 57 54 1 46 6.
4A7A6036G 72 38 50 4 56 8 60 4 59 8 57 2 55 2 49 2. 4A7A6048G 73 44 2 50 4 58 9 63 1 63 57 4 53 6 47 4. 4A7A6060E 74 42 2 53 8 57 8 66 65 7 57 7 58 4 51 7. Note Rated in accordance with AHRI Standard 270 2008. 4 12 1200 14, Accessory Description and Usage AHRI Standard Capacity Rating Conditions. Rubber Isolators 5 rubber donuts to isolate condens AHRI STANDARD 210 240 RATING CONDITIONS. ing unit from mounting frame or pad Use on any application A Cooling 80 F DB 67 F WB air entering indoor coil. where sound transmission needs to be minimized 95 F DB air entering outdoor coil. B High Temperature Heating 47 F DB 43 F WB air entering. Extreme Conditions Mounting Kit Bracket kits to secure outdoor coil 70 F DB air entering indoor coil. ly mount condensing unit to a frame or pad without removing C Low Temperature Heating 17 F DB 15 F WB air entering. any panels Use in areas with high winds or on commercial outdoor coil 70 F DB air entering indoor coil. rooftops etc D Rated indoor airflow for heating is the same as for cooling. Low Ambient Cooling For low ambient cooling below 55 AHRI STANDARD 270 RATING CONDITIONS Noise. see Application Guide APP APG013 EN rating numbers are determined with the unit in cooling opera. tandard Noise Rating number is at 95 F outdoor air. 12 1200 14 5,Nomenclature, 4 A 7 A 6 0 3 6 E 1 0 0 0 A A Gas Furnaces A U D 2 B 0 8 0 A C V 3 2 A A. Outdoor Units,Refrigerant Type,American Standard,Product Type. 6 Split Heat Pump,7 Split Cooling,Product Family,Z Leadership Two Stage. X Leadership,R Replacement Retail,M or B Basic,A Light Commercial.
Family SEER,3 13 6 16 0 20,Split System Connections 1 6 Tons. Nominal Capacity in 000s of BTUs,Major Design Modifications. Power Supply,1 200 230 1 60 or 208 230 1 60,3 200 230 3 60. 4 460 3 60,Secondary Function,Minor Design Modifications. Unit Parts Identifier,4 T E E 3 F 3 6 A 1 0 0 0 A A.
Air Handlers,Residential Coils 4 T X C B 0 0 1 C C 3 H C A A. Refrigerant Type Residential,Refrigerant Type,Application. Product Family,TE Fully Convertible,TG Semi Convertible. Heat Pump or Convertible Coil,TF Front Return,Coil Design. Product Family X Direct Expansion Evaporator Coil,E Leadership Variable Speed Product Family.
P Leadership C Cased A Coil,C Replacement Retail A Uncased A Coil. B Basic F Cased Horizontal Flat Coil,Flow Control Coil Width Cased Uncased. 0 No Flow Control A 14 5 13 3,B 17 5 16 3,3 Nonbleed TXV C 21 0 19 8. Feature Identifier D 24 5 23 3,0 Standard Unit H 10 5. F Air Tite Refrigerant Line Coupling,Nominal Capacity in 1000 s BTUH.
Model Number Distinguisher,Major Design Change,Major Design Change. Power Supply,1 Single Phase Efficiency,C Standard, Electrical Connection S Hi Efficiency Derived from 10 SEER products. 0 Pig Tails,Refrigerant Control,B Circuit Breaker 3 TXV Non Bleed. D Pull Disconnect,Coil Circuitry, Future Option Factory Installed Heater Nominal KW Value H Heat Pump. Minor Design Modifications,Airflow Configuration,Unit Parts Identifier A Upflow Only.
U Upflow Downflow, NOTE There will be a phase in of new model numbers for new H Horizontal Only. air handlers over next 2 years C Convertible Upflow Downflow Left or Right Airflow. Minor Design Change,Unit Parts Identifier,6 12 1200 14. Electrical,Schematic Diagrams,SEE LEGEND,4A7A6024G 036G. Printed from D157614P01,12 1200 14 7,Electrical,Schematic Diagrams. SEE LEGEND,4A7A6048G 060E,Printed from D156975P03,8 12 1200 14.
Electrical,Schematic Diagrams,12 1200 14 9,Dimensions. 4A7A6 Outline Drawing,Note All dimensions are in MM Inches. MODELS BASE A B C D E F G H J K, 4A7A6024G 4 1045 41 1 8 946 37 1 4 870 34 1 4 5 8 3 8 152 6 98 3 7 8 219 8 5 8 86 3 3 8 711 28. 4A7A6036G 4 1147 45 1 8 946 37 1 4 870 34 1 4 3 4 3 8 152 6 98 3 7 8 219 8 5 8 86 3 3 8 813 32. 4A7A6048G 4 1147 45 1 8 946 37 1 4 870 34 1 4 7 8 3 8 152 6 98 3 7 8 219 8 5 8 86 3 3 8 813 32. 4A7A6060E 4 1147 45 1 8 946 37 1 4 870 34 1 4 1 1 8 3 8 152 6 98 3 7 8 219 8 5 8 86 3 3 8 813 32. From Dwg D152862 Rev 26,10 12 1200 14,Mechanical,Specifications. General Condenser Coil, The 4A7A6 is fully charged from the The outdoor coil provides low airflow.
factory for matched indoor section resistance and efficient heat transfer. and up to 15 feet of piping This unit is The coil is protected on all four sides by. designed to operate at outdoor ambient louvered panels. temperatures as high as 115 F Cooling Low Ambient Cooling. capacities are matched with a wide se As manufactured this unit has a cool. lection of air handlers and furnace coils ing capability to 55 F For low ambient. that are AHRI certified The unit shall be cooling below 55 see Application Guide. certified to UL 1995 Exterior is designed APP APG014 EN. for outdoor application,Unit casing is constructed of heavy. gauge G60 galvanized steel and paint,ed with a weather resistant powder paint. on all louvers and panels Corrosion and,weatherproof CMBP G30 DuraBase. Refrigerant Controls,Refrigeration system controls include. condenser fan compressor contactor,and high pressure switch High and low.
pressure controls are inherent to the,compressor A factory installed liquid line. drier is standard,Compressor,The Duration 2 stage compressor. features internal over temperature and,pressure protection and hermetic motor. Other features include roto lock suction,and discharge refrigerant connections. centrifugal oil pump and modular plugs,for electrical connections.
12 1200 14 11, American Standard Heating Air Conditioning American Standard Heating Air Conditioning has a policy of continuous product and product data. www americanstandardair com improvement and it reserves the right to change design and specifications without notice.

Related Books

Komponen instalasi tenaga listrik

Komponen instalasi tenaga listrik

pipa/conduit jenis PVC atau saluran tertutup. Sehingga tidak mudah menjadi sasaran gigitan tikus, dan apabila ada isolasi yang terkelupas tidak tersentuh langsung oleh orang. Kabel NYA *Digunakan untuk kabel instalasi listrik rumah atau gedung dan sistem tenaga. Kabel NYM berinti lebih dari 1, memiliki lapisan isolasi PVC (biasanya warna putih atau abu-abu), ada yang berinti 2, 3 atau 4 ...

Euripides: IPHIGENEIA AT AULIS. Brief notes by P. G. Brown

Euripides IPHIGENEIA AT AULIS Brief notes by P G Brown

C. Collard and J. Morwood, Euripides: Iphigenia at Aulis, 2 Vols., 2017. T. Tarkow and S. MacEwan - Iphigenia at Aulis, 1988, Bryn Mawr Commentaries. Erich Segal (ed.) Euripides: A Collection of Critical Essays, 1968. D.J. Conacher, Euripidean Drama, Myth Theme and Structure, 1967. Other books: Euripides and His Age, G. Murray (1913) The Imagery of Euripides, S. Barlow (1971) The Greek Tragic ...

Market access between UK and Gibraltar: a consultation

Market access between UK and Gibraltar a consultation

Gibraltar to develop similar provisions in Gibraltar law to enable UK firms to access the Gibraltar market. 1.2 Constitutionally, Gibraltar is an Overseas Territory with internal self-government. Although it is a distinct jurisdiction from the UK, the UK retains responsibility for its external relations, as well as defence and internal security ...

The Shape of Gibraltar in the aftermath of Brexit

The Shape of Gibraltar in the aftermath of Brexit

The Shape of Gibraltar in the aftermath of Brexit George Macquisten (History and International Relations student at the University of Exeter) Published in 2017 by The Bruges Group, 214 Linen Hall, 162-168 Regent Street, London W1B 5TB www.brugesgroup.com Follow us on twitter @brugesgroup Find our facebook group: The Bruges Group Bruges Group publications are not intended to represent a ...

Immigration Judge Benchbook Index - Higher Intellect

Immigration Judge Benchbook Index Higher Intellect

Immigration Judge Benchbook Index (October 2001) Chapter One - Evidence I. Overview A. In General B. Burden of Proof and Presumptions II. Specific Areas A. Documentary Evidence B. Admissions Made By Counsel C. Testimony D. The Exclusionary Rule for Evidence Obtained in Violation of the Fourth Amendment Prohibition Against Unlawful Search and ...

DOCUMENT RESUME Straus, Murray A.; Hamby, Sherry L ...

DOCUMENT RESUME Straus Murray A Hamby Sherry L

AUTHOR Straus, Murray A.; Hamby, Sherry L.; Finkelhor, Daniv; Moore, David; Runyan, Desmond TITLE Identification of Child Maltreatment with the Parent-Child. Conflict Tactics Scales: Development & Psychometric Data for a National Sample of American Parents. SPONS AGENCY New Hampshire Univ., Durham.; National Inst. of Mental. Health (DHHS), Bethesda, MD. PUB DATE 1997-03-00 NOTE 27p.; Paper ...

Aviva plc - Results presentation FY 2017

Aviva plc Results presentation FY 2017

compensation to our customers; the effect of fluctuations in share price as a result of general market conditions or otherwise; the effect of simplifying our operating structure and activities; the effect of a decline in any of our ratings by rating agencies on our standing among customers, broker-dealers, agents, wholesalers and other distributors of our products and services; changes

Characterisation of secondary phases in Ni-base superalloy ...

Characterisation of secondary phases in Ni base superalloy

superalloy Rene 65 Tomasz Wojcik, Markus Rath & Ernst Kozeschnik To cite this article: Tomasz Wojcik, Markus Rath & Ernst Kozeschnik (2018) Characterisation of secondary phases in Ni-base superalloy Rene 65, Materials Science and Technology, 34:13, 1558-1564, DOI: 10.1080/02670836.2018.1505227

Horizontal Machining Center - Bulmakmetal Ltd

Horizontal Machining Center Bulmakmetal Ltd

Horizontal Machining Center Achieves stable machining accuracies that are unsurpassed as a general purpose horizontal machining center with superb thermal deformation control system, based on Okuma's original Thermo-Friendly Concept. This high-performance machine gives improved productivity with a large machining area, high-speed rapid feedrate, and reduced running costs thanks to longer ...

ALABAMA MINE MAP REPOSITORY

ALABAMA MINE MAP REPOSITORY

STATE OF ALABAMA DEPARTMENT OF LABOR . Fitzgerald Washington. Commissioner. INSPECTIONS DIVISION Brian J. Wittwer Acting Director ABANDONED MINE LAND PROGRAM Chuck Williams State Mine Land Reclamation Supervisor ALABAMA MINE MAP REPOSITORY DIRECTORY OF UNDERGROUND MINE MAPS . By, Charles M. Whitson, PE Mining Engineer Birmingham, Alabama 2013