GHPD Rotary Lobe Positive Displacement Pump, The GHPD rotary lobe positive displacement pump was Design. designed to meet specific processing needs in the Dairy Gearcase. Food Beverage Chemical Pharmaceutical and Biotech The gearcase is constructed of epoxy coated cast iron. industries Meeting the demands of the sanitary The main drive shaft is accurately timed with an auxiliary. industry the GHPD is authorized to carry the 3A symbol shaft each of which drives a single rotor This precise. and is the first rotary lobe pump to be USDA Dairy ac timing allows for tight tolerances between the rotors and. cepted for CIP clean in place The GHPD has also been rotorcase allowing the most efficient transport of product. installed in egg processing lines with USDA acceptance Both shafts are supported by heavy duty load bearings. for CIP An innovative design allows for gentle product. handling while providing efficient transport of viscous Rotorcase product contact surfaces. liquids All product contact surfaces are AISI T316 stainless steel. Trilobe T316 stainless steel rotors are standard The. Working Principle HyClean Shaft seals allow for complete cleaning of the. seal area during CIP operations Vertical porting is. The GHPD has two stainless steel rotors that operate by. standard and offers special advantages including, the principle illustrated in Figure 4 When operating at. optimum speeds this pump provides gentle handling of Self draining capability. both viscous and water like products Self venting capability. Utilize bottom port for inlet when tanks have low outlet. Fig 1 GHPD vertical ports Utilize top port for inlet when connecting direct from. bottom of tanks,Ideal entrance for hopper feed applications when. equipped with enlarged rectangular inlets,Fig 3 HyClean seal. Fig 4 Principle,Fig 2 GHPD horizontal ports,GHPD Rotary Lobe Positive Displacement Pump.
Performance Data,Data for guidance only,500 Based on 0 PSI at. 832 pump inlet,Capacity GPM, 100 300 1 000 3 000 10 000 30 000 100 000 300 000 1 000 000. Viscosity cps,Flows Pressures Connections, GHPD Port Size inches Max Pressure PSIG Max Nominal Max. Capacity Displacement Speed, Standard Optional Standard High GPM USG 100 rev RPM. 322 1 115 14 1 4 1000,332 1 5 75 22 2 2 1000,422 1 5 150 220 34 3 4 1000.
432 2 1 5 100 150 47 4 8 1000,522 2 1 5 150 220 71 7 0 1000. 532 2 5 2 100 150 100 10 1 1000,622 2 5 2 150 300 145 14 6 1000. 632 3 100 220 208 20 9 1000,722 3 150 300 184 30 6 600. 732 4 100 220 266 44 4 600,822 4 150 300 324 65 0 500. 832 6 100 220 466 93 2 500,Standard connections GC Clamp.
Sanitary connections are available according to required standard SMS DIN BS. Flanged connections and BSP available,Enlarged and rectangular inlets available. GHPD Rotary Lobe Positive Displacement Pump,Dimensions inches. Fig 5 Dimensions horizontal ports, Size A B C D E F G HB HT J KS KW L M N P Q R S T U. 322 1 3 74 3 54 6 61 0 39 16 1 57 2 68 4 45 1 18 0 71 5 11 12 1 71 4 88 3 15 0 59 4 92 3 94 3 15 0 39. 332 1 5 3 74 3 54 6 61 0 39 16 1 57 2 68 4 45 1 18 0 71 5 11 52 1 91 4 88 3 15 0 59 4 92 3 94 3 15 0 39. 422 1 5 4 13 4 53 8 35 0 63 22 1 97 3 35 5 71 1 26 0 96 6 13 39 2 38 5 16 3 94 0 75 6 06 4 88 3 94 0 47. 432 2 4 13 4 53 8 35 0 63 22 1 97 3 35 5 71 1 26 0 96 6 13 74 2 52 5 16 3 94 0 75 6 06 4 88 3 94 0 47. 522 2 4 92 5 43 9 96 0 71 28 2 36 3 94 6 89 1 57 1 22 8 17 13 3 25 6 89 4 92 1 18 8 27 6 06 4 92 0 55. 532 2 5 4 92 5 43 9 96 0 71 28 2 36 3 94 6 89 1 57 1 22 8 17 64 3 43 6 89 4 92 1 18 8 27 6 06 4 92 0 55. 622 2 5 5 91 6 42 11 93 0 79 38 3 15 4 53 8 31 2 48 1 61 10 21 30 3 98 8 86 5 91 1 38 10 04 7 24 5 91 0 55. 632 3 5 91 6 42 11 93 0 79 38 3 15 4 53 8 31 2 48 1 61 10 21 97 4 33 8 86 5 91 1 38 10 04 7 24 5 91 0 55. 722 3 6 89 7 68 14 45 0 79 45 4 33 5 31 10 04 2 76 1 91 14 24 67 3 82 10 98 7 09 1 38 10 83 8 27 7 09 0 55. 732 4 6 89 7 68 14 45 0 79 45 4 33 5 31 10 04 2 76 1 91 14 25 57 4 25 10 98 7 09 1 38 10 83 8 27 7 09 0 55. 822 4 7 48 8 86 16 73 0 79 48 4 33 6 10 11 61 2 76 2 03 14 29 09 4 90 10 47 10 24 1 57 14 57 8 66 7 48 0 55. 832 6 7 48 8 86 16 73 0 79 48 4 33 6 10 11 61 2 76 2 03 14 30 43 5 51 10 47 10 24 1 57 14 57 8 66 7 48 0 55. All dimensions in inches except F and KW mm,Fig 6 Dimensions vertical ports. Size A B C D E F G J K L M N P Q R S T U X, 322 1 3 74 4 45 8 19 0 63 16 1 54 1 18 5 11 06 1 97 4 57 3 15 0 47 4 09 4 09 3 15 0 39 0 89.
332 1 5 3 74 4 45 8 19 0 63 16 1 54 1 18 5 11 42 2 17 4 57 3 15 0 47 4 09 4 09 3 15 0 39 0 89. 422 1 5 4 13 5 77 9 90 0 79 22 1 97 1 26 6 13 50 2 64 4 88 3 94 0 47 4 88 4 88 3 94 0 47 1 18. 432 2 4 13 5 77 9 90 0 79 22 1 97 1 26 6 13 90 2 80 4 88 3 94 0 47 4 88 4 88 3 94 0 47 1 18. 522 2 4 92 6 89 11 81 0 87 28 2 28 1 57 8 17 28 2 68 6 02 6 10 0 59 7 28 6 06 4 92 0 47 1 48. 532 2 5 4 92 6 89 11 81 0 87 28 2 28 1 57 8 17 68 2 83 6 02 6 10 0 59 7 28 6 06 4 92 0 47 1 48. 622 2 5 5 91 8 39 14 61 0 98 38 3 15 2 48 10 21 26 3 07 7 76 7 87 0 67 9 21 7 24 5 91 0 55 1 89. 632 3 5 91 8 39 14 61 0 98 38 3 15 2 48 10 21 93 3 39 7 76 7 87 0 67 9 21 7 24 5 91 0 55 1 89. 722 3 6 89 10 12 17 01 1 18 45 4 33 2 76 14 24 69 3 62 10 40 7 87 0 79 9 45 8 66 7 09 0 55 2 36. 732 4 6 89 10 12 17 01 1 18 45 4 33 2 76 14 25 99 4 06 10 40 7 87 0 79 9 45 8 66 7 09 0 55 2 36. 822 4 7 48 11 61 19 09 1 18 48 4 33 2 76 14 29 09 4 72 10 51 10 24 0 79 11 81 9 84 8 27 0 55 2 76. 832 6 7 48 11 61 19 09 1 18 48 4 33 2 76 14 30 43 5 47 10 51 10 24 0 79 11 81 9 84 8 27 0 55 2 76. Maximum Size of Solids Fig 7 Direction of Flow, Max size of solids inches Vertical porting D denotes location of drive shaft. Bi lobe Tri lobe,GHPD rotors rotors Inlet Top Inlet Bottom. 322 5 16 7 32,332 5 16 7 32,422 5 16 7 32 D D,432 1 2 7 32. 522 1 2 11 32,532 5 8 7 16, Horizontal porting D denotes location of drive shaft. 622 5 8 7 16,632 7 8 19 32,Inlet Right Inlet Left,722 7 8 19 32.
732 11 16 23 32,822 11 16 23 32,832 17 16 15 16 D,Shaft Seals. Single HyClean seal standard with rotating face, stainless steel and stationary face carbon Material Grades. Single flushed HyClean seal Elastomers see under shaft seals. Double flushed mechanical seal Shaft seal stationary silicon carbide or silicon carbide. Steam barrier for aseptic pumping inserted,O ring seal Shaft seal rotary silicon carbide. Packed Gland,Packed Gland with flush Ordering, The selection of the size and speed of a rotary lobe pump. Elastomers depends upon many product characteristics Contact. your pump supplier for selection of the correct pump and. EPDM std nitrile NBR FPM PTFE encapsulates and,drive unit.
Options Please provide the following for accurate selection of your. Equipment Product to be pumped, Built in pressure relief valve cover Capacity during process and CIP SIP. PD 65403US 9906 E1, Heating cooling saddles applied to rotorcase Discharge pressure. Heating cooling jacket applied to front cover not Suction conditions. available with relief valve Line size,Horizontal porting Viscosity. Bilobe rotors Specific gravity, Non galling bilobe alloy rotors Operating temperature. High temperature SS rotors up to 392 F Maximum temperature and pressure during. Complete pump units pump SS base plate complete process and CIP SIP. with coupling and guard gearmotor mechanical Connection type. variable speed drive variable frequency drive Drive specification. Electropolish surface finish, Contact Alfa Laval Flow Inc for application assistance.
Alfa Laval Flow Inc,P O Box 581909,8201 104th Street. Pleasant Prairie WI 53158 0909,Telephone 800 558 4060.


Related Books

Fire Pump Selection Guide - FAMA

Fire Pump Selection Guide FAMA

displacement pumps used in the fire service are piston pumps, rotary vane pumps, and gear pumps. Each time the pump spins, a specific amount of water is moved. Because of this action, positive displacement pumps are capable of delivering constant flow at very high pressures at a constant speed.

Experiment (9): Centrifugal pump Introduction

Experiment 9 Centrifugal pump Introduction

Experiment (9): Centrifugal pump Introduction: Pumps fall into two main categories: positive displacement pumps and rotodynamic pumps. In a positive displacement pump, a fixed volume of fluid is forced from one chamber into another. The centrifugal pump is, by contrast, a rotodynamic machine. Rotodynamic (or simply dynamic) pumps impart momentum to a fluid, which then causes the fluid to move ...

HortiMaX - Blistech International

HortiMaX Blistech International

From the design phase ... HortiMaX FertiMiX HortiMaX PT-meter . The market is changing ... High Mid Low Wide-span Glass or Poly

Prolongevity hormone FGF21 protects against immune ...

Prolongevity hormone FGF21 protects against immune

Prolongevity hormone FGF21 protects against immune senescence by delaying age-related thymic involution Yun-Hee Youma, Tamas L. Horvatha, David J. Mangelsdorfb,c, Steven A. Kliewerb,d, and Vishwa Deep Dixita,e,1 aSection of Comparative Medicine and Program on Integrative Cell Signaling and Neurobiology of Metabolism, Yale School of Medicine, New Haven,

Excellent Integrated System Limited

Excellent Integrated System Limited

Enhanced Poly-Phase Hi gh-Performance Wide-Span Energy ... The M90E32AS is a poly-phase high performance wide-dynamic ... Excellent Integrated System Limited.

Algorithmic Information Theory and Kolmogorov Complexity

Algorithmic Information Theory and Kolmogorov Complexity

Algorithmic Information Theory and Kolmogorov Complexity Alexander Shen, ? Uppsala University, Computing Science Department, Independent University of Moscow, [email protected] November 19, 2007 Abstract This document contains lecture notes of an introductory course on Kolmogorov complexity.

AN-639 (Rev. A) Application Note - Analog Devices

AN 639 Rev A Application Note Analog Devices

The site contains all the single-phase and poly-phase ... Creeping is the phenomenon in which the energy meter still ... Good high current performance, wide dynamic ...

Poly-Phase High-Performance Wide-Span Energy Metering IC ...

Poly Phase High Performance Wide Span Energy Metering IC

90e32a poly-phase high-performance wide-span energy metering ic 4 april 2, 2013 5.2 partial measurement mode calibration ...

Published - maxpapers

Published maxpapers

Cambridge Ordinary Level BIOLOGY 5090/11 Paper 1 Multiple Choice May/June 2017 MARK SCHEME Maximum Mark: 40 Published This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of the examination. Mark schemes should be read in conjunction with the question paper and the Principal Examiner Report for Teachers.

Intel Desktop Board D845GEBV2/D845GERG2

Intel Desktop Board D845GEBV2 D845GERG2

Intel Desktop Board D845GEBV2/D845GERG2 Technical Product Specification iv CAUTION Cautions are included to help you avoid damaging hardware or losing data.