ICT Labs Summer School on Smart Energy,Function Method Examples UK. Generation Steam gas water or wind nPower E On British Energy. turbines driving alternators SELCHP Barking Power, Transmission 275kV 400kV overhead National Grid owner and. lines the national grid operator,Scottish Power owner. Distribution 132kV 33kV 11kV UK Power Networks Scottish. overhead lines and cables and Southern,Supply Purchase of energy on EDF Energy. wholesale market resell E On British Gas, Consumption Motors heaters lighting Industrial commercial and.
supplies for electronic domestic consumers, In the UK the unbundling of the supply side is known as ownership unbundling in which a company. can only operate in one of the functions Some of the large energy companies have split their. business into subsidiary companies to comply with this but then must ensure there is no leakage of. commercial information or influence between the subsidiaries. There are two ways to describe the relationships between the functions based on either the trading. relationships or on the flow of energy, The trading of electricity in the UK has two fully competitive markets The first is the generation market. between generators on the one hand and on the other hand large consumers and electricity supply. companies wholesalers of electricity This market is bilateral and allows parties to trade energy in. advance of its actual delivery on any timescale they wish from half hour blocks to yearly. commitments for instance The generation market is frozen one hour ahead of delivery so that the. technical side of grid operation can be accommodated The second market is the supply market. between the energy supply companies and domestic and small commercial consumers Consumers. can change their suppliers as they choose but will generally have a simple tariff that is not subject to. the half hour price variations of the main generation market. The trading view of the unbundled industry makes no mention of how the energy is actually. transported The second view addresses this Most generation is large scale and connected directly to. a bulk transmission network the covers the country This network delivers the energy to bulk supply. points which feed a lower voltage distribution network that delivers the energy to the final consumers. There are some small generators and plans for many more that connect directly to the distribution. system Similarly there are some very large consumers who connect directly to the transmission. The British transmission system which is operated by National Grid Electricity Transmission Limited. NGETL NGETL also owns the transmission network in England and Wales but in Scotland it is. owned by Scottish Power ETL and Scottish Hydroelectic Limited The separation of ownership of. transmission from operation of transmission is taken further in the USA where Independent. Transmission Operators ISOs operate systems in which they have no ownership of the assets. TCG Imperial College 1 2,ICT Labs Summer School on Smart Energy. Participants in Wholesale and Retail Electrical Energy Markets and. the Ancillary Services Market, Energy Flows Between Generators and Consumers via Transmission and. Distribution Networks,TCG Imperial College 1 3,ICT Labs Summer School on Smart Energy.
The GB Transmission Network,TCG Imperial College 1 4. ICT Labs Summer School on Smart Energy, There are 15 distribution network operators DNOs in the UK. 1 2 Transmission and Distribution, There are many ways in which a transmission and distribution system could be configured but. systems throughout the world have the same features. 1 2 1 Voltage Source System, A cable or overhead line has a series impedance and a shunt admittance The series impedance is. the small resistance of the copper or aluminium etc wire and the inductive reactance of the wire. path The shunt admittance is the very small conductivity of the insulators and the capacitive. susceptance between wires,PLoss I 2R,PLoss V 2G, Power losses occur in the wire resistance I R and the insulator conductance V G In general.
insulators are closer to ideal than conductors and the power loss in the insulator is often negligible. Considering only conductor power loss a voltage source variable current system has losses that. TCG Imperial College 1 5,ICT Labs Summer School on Smart Energy. decrease as the load decreases A current source system would have constant loss for any load. including no load,1 2 2 Impedance Matching, Amplifiers are used with a load impedance matched to the output impedance in order to maximise. power transfer Maximum power transfer is not the same as maximum efficiency In fact with resistive. impedances resistance matching gives 50 efficiency For instance a 600MW power station. generator would lose 300MW of its power in the very hot cables to the loads The main. consideration with a power system is to maintain the consumer s voltage within a few percent of its. nominal value For this reason the network is run with low source impedance and high load. I VR PR PR P P,V V I VR V2,1 2 3 A Variety of Voltages. Power dependent on the V I product can be transmitted with any value V and a corresponding value. of I The loss is related to I and so higher voltages reduce power loss and increase efficiency At very. high voltages the V G losses become a significant factor Voltages of between 500kV and 100kV are. used for transmission Distribution involves lower power levels on each route The capital cost of H V. equipment is prohibitive compared with the small saving in running costs losses Medium voltages of. the between 100kV and 10kV are used Safety considerations require most users to be supplied at. voltages of 250V or less,1 2 4 Alternating Current and Voltage. The traditional way and still the only cost effective way of changing voltage levels in a power system. is the transformer Transformers require an AC system because voltage can only be supported by. changing flux E N d dt and AC is the only way of obtaining continuously changing but finite flux. There are exceptions DC transmission is used to link AC systems of different characteristics and DC. is used in some isolated distribution systems such as on large ships. 1 2 5 Sinewave Voltage, The voltages and currents of inductors and capacitors are related by differential equations A sine.
wave is the only AC form that will ensure that all voltage drops and leakage currents in the system are. the same form as the source waveform, It is often supposed that generators naturally produce sinewave voltages This is true of simplistic air. cored machines but not of realistic iron cored machines Considerable design effort is required to. achieve sinewave voltages,TCG Imperial College 1 6. ICT Labs Summer School on Smart Energy,1 2 6 50 60Hz. The frequency of an AC power system is directly related to the rotational speed of the generators. 3 000 or 3 600 rpm was a sensible choice considering the bearings and materials available when. systems evolved Higher frequencies would reduce transformer size but cause larger inductive. voltage drops and capacitive leakage currents Lower frequencies cause noticeable lighting flicker. and require larger transformers Higher frequencies are used where weight and size are an issue. such as on ships and aircraft,1 2 7 Three Phases, Generators are best built with a large number of coils distributed around the machine So that a. practicable number of connections can be used outside the machine the coils are grouped into. phases The choice of three phases is a sensible compromise between number of connections and. good utilisation of the machine More than one phase is essential to facilitate smoothly rotating AC. 1 3 Electricity Grid Operation, A grid system is expected to provide a secure source of energy whenever a customer demands it.
The grid operator must balance the demand with the supply of energy from various generators. There is a daily pattern of load variation that is reasonably predictable It is different at weekends and. different from one season to the next The highest demand is in the early evening of a winter. weekday The absolute peak varies slightly from year to year depending on the weather conditions In. 2009 it was 60 2 GW in 2005 it was 61 7 GW and in 2006 it was 59 1 GW. The system operator must plan for unusual demand patterns such as television pick up This is the. sudden increase in load when a popular television programme ends This can provoke a rise of 1000. MW in demand in a matter of a few minutes Major television events create even larger changes The. largest events are over 2 000 MW,TCG Imperial College 1 7. ICT Labs Summer School on Smart Energy, Most TV events can be predicted reasonably well based on previous experience It is highly unusual. events that cause problems It would also seem that the more diverse TV and entertainment market. that now exists means that the TV pick up is less severe because the audience for each TV. programme is less, The largest ever TV pick up in the UK was 2 800 MW of demand after the penalty shootout in an. England v Germany world cup semi final in 1990, An example of a highly unusual event causing the system operator to work hard to maintain a stable. system was the two minute silence at 11am on 14 September 2001 in remembrance of the deaths. on 11 September, In the minutes before and during the silence some 2 500 MW of load was switched off This requires.
two large power stations to be removed from the system very quickly We can tell that this was not. achieved quickly enough because the grid frequency rose above its target range When generation. exceeds demand the excess energy builds up in the inertia of the generators and the frequency rises. The missing 2500 MW of load reappeared over the next 5 minutes and because there was now a. shortage of generation the frequency briefly dipped below its target range. A more recently National Grid seems to have done a remarkably good job of managing some difficult. demand pick up and drop off associated with the Royal Wedding They would have looked back in the. records more than 10 years for the last similar wedding but would have found direct comparison tricky. because of the changes in TV viewing habits over ten years and the fact that this time a back holiday. TCG Imperial College 1 8,ICT Labs Summer School on Smart Energy. was declared and last time it was a normal work day Nonetheless they managed to stop any large. frequency excursions occurring despite swings in demand of more than 3 000 MW over an hour. actually a lot slower than a 2 minute silence, Faults in either generator or the transmission network itself cause system operators the greatest. problems because these are very fast events The GB system operators to a 1320 MW loss of in feed. standard The large 2 000 MW coal fired plat such as Radcliffe on Soar or Drax have four 500 MW. turbine generators run from two boilers with a double circuit connection to the grid No single fault can. cause all 2 000 MW to be lost in one go The Sizewell B pressurised water reactor has two 660 MW. turbine generators but only one steam circuit so the whole lot can get shut down in one go if there is a. fault in the steam circuit So National Grid carries enough reserve to deal with this loss if Sizewell B is. running In May 2008 Sizewell B did shut down unexpectedly which would have been OK but for the. fact that a 500 MW generator at Longannet had also been lost unexpectedly about 2 minutes earlier. The loss of 1 582 MW of actually generation in such a short time was not covered by the reserve and. the frequency dropped below the operational limit 49 8 Hz and then below the statutory limit. 49 5 Hz a breach of National Grid s licence agreement unless an exceptional event The frequency. reached about 49 15 Hz before its fall was arrested Then an unfortunate thing happened A lot of. small wind turbines other small generators adding up to about 300 MW disconnected 3 minutes. later These had been fitted with protection relays that interpreted a 3 minute under frequency event. as break up of the system and were shut down to prevent electrical islands forming The result was. that the frequency dropped even further and this lead to automatic under frequency load shedding. Put more bluntly supply to parts of certain towns were shut off. TCG Imperial College 1 9,ICT Labs Summer School on Smart Energy. Electricity in Great Britain is traded in bilateral contracts between generators and large customers. including the energy supply companies under a system known as BETA Each generator and. purchaser must declare its future output or demand half an hour before real time the gate closure. time These predictions of generation and load are never exactly realised when the time comes. Generators sometimes develop faults wind turbines have too little or too much wind the televised. football match goes into extra time the forecast early morning frost does not happen The system. operator National Grid PLC must run a second by second balancing operation using one power. station to make up for losses in the system and the mismatch between supply and demand It does. this by monitoring the system frequency and adjusting its power accordingly This is known as primary. response Additional slower response known as secondary response can be instructed to respond. by the National Grid control centre If the balancing operation fails the voltage and frequency of the. system will fall and loads will have to be shed in order to avoid system wide collapse Some of the. other power stations around the system will be used to regulate the voltage of the grid through. adjustment of their excitation National Grid contracts certain generators to provide these services To. recover these costs National Grid applies use of system charges to all users of the grid and out of. balance charges to users who exceed or fall short of their predicted use. A grid system is an efficient means of transporting energy but there are some losses The local. distribution system is less efficient because of the lower voltages used Of the approximately 10p per. kWh charged to domestic consumers in the UK about 50 is accounted for by costs of generating. and the remainder by the losses and operating costs in transmission 5 losses and operating costs. in distribution 30 and the metering billing costs 15. TCG Imperial College 1 10,ICT Labs Summer School on Smart Energy. 1 4 Revision of AC Power Calculation, We chose the cosine as the standard sinusoidal signal and note a cosine is the real part of a complex.
exponential,e j cos j sin,v Re Ve j t Re Ve j e j t. In this final representation the signal has three parts. V is the magnitude of the signal,e j represents phase angle of the signal. e j t represents the sinusoidal variation at the system frequency. We only need to retain the magnitude and phase angle which together form the phasor. The ratio of voltage and current phasors gives impedance Z in its complex form Re Z is resistance. and Im Z is reactance both measured in ohms The resistance of a conductor under dc and ac. conditions is the same unless factors such as skin effect are relevant Skin depth in copper at 50Hz is. 9 3 mm only conductors thicker than this experience significant skin effect Reactance is a feature of. energy storage components for example inductors and capacitors. Z L jX L j L,Z C jX C j, Note how the complex impedance creates the expected phase difference between the voltage and. current vectors,For and inductor,For a capacitor, With the definitions of phasors and complex impedances in place all the standard circuit analysis. techniques for DC steady state can be applied to sinusoidal steady state provided vector rather than. scalar arithmetic is used,TCG Imperial College 1 11.
ICT Labs Summer School on Smart Energy,1 4 1 Power Real and Otherwise. Power is energy flow and is measured in watts equivalent to joules per second Instantaneous. power is the product of voltage and current at that instant. The voltages and currents are defined using the passive convention shown in the figure A positive. value of p represents energy flowing into the component and a negative value is energy flowing out. p t vAB t iAB t, A v AB The energy flow may be occurring for one or both of two reasons. 1 Energy storage such as occurs in inductors and capacitors or. 2 Dissipation such as the conversion of electrical energy to heat. kinetic energy or em radiated energy, If the instantaneous power is averaged under steady state conditions then the average includes only. the dissipative terms because the energy storage components store and release equal amounts of. energy over a cycle as is necessary for steady state to exist. Resistor pR vR i, An average power is calculated by integrating the instantaneous power over one cycle and dividing by. the period The average power is also known as real power. P p 0 p t dt i t v t dt,TCG Imperial College 1 12,ICT Labs Summer School on Smart Energy.
The stored and returned power is known as reactive power and given the symbol Q Because it is not. dissipative it should not have the units of watts but a new unit of the same dimensions known as. volt amperes reactive VAr, Most electrical equipment has a voltage limit and a current limit These combine to give a volt. ampere rating or apparent power rating The unit of apparent power is VA It does not specify how. much of the volt ampere is real dissipative power and how much reactive temporary storage. 1 4 2 Average Power, For a resistor we expect a non zero result for the average power. R cos2 t d t,2 I V R 1 cos 2 t d t, If we perform the average using the i R form of the power equation we can see that the mean of the. square of the current is an important definition,2 i t R d t R. where I MS 2, The mean square is an inconvenient term to deal with and has units of A it is better to define a root.
mean square form of average current or voltage for use in these calculations. I RMS i t d t,We can then state,PR 12 I VR,I RMS VRRMS or I R. For a sinusoidal waveform there is a simple relationship between the peak and RMS measures. I RMS I cos t d t, The use of RMS is so widespread in power engineering that we expect magnitudes of all voltages and. currents to be quoted in RMS The superscript RMS is dropped and we assume a quantity is RMS. unless told otherwise, The average power of the inductor is zero because all energy stored in one half of the cycle is released in. TCG Imperial College 1 13,ICT Labs Summer School on Smart Energy. PL pLAvg p L d t I VL sin t cos t d t,L 2 sin 2 t d t.
1 4 3 General Case for Calculating Power, To calculate power for general components not just the basic R L and C the real power is given by. the component of voltage that is in phase with the current the component that is resistor like. The real power can be expressed as a dot product,where V I and. Note that the convention here is that the magnitude of a vector is shown by dropping the over bar. Because VP IZ cos the real power can also be written as P I 2 Re Z. By analogy we define the reactive in terms of the component of voltage Vq in quadrature 90 out of. phase with the current,Q I VQ I V sin,Q I 2 Im Z, The apparent power is defined as the product of voltage and current without regard to the angle. The ratio of real power to apparent power is defined as the power factor For the sinusoidal case it is. related to the impedance angle,TCG Imperial College 1 14. ICT Labs Summer School on Smart Energy, It can also be shown that the real power is given by the real part of the voltage vector multiplied by the.
conjugate of the current vector This leads to a definition of complex power that is a convenient. method of finding real and reactive powers from voltages and currents in vector phasor form. S V I P jQ, Recap We have four types of power instantaneous real reactive and apparent Only the first two are. really about converting energy from one form to another and are measured in watts W Apparent. power is not necessarily about energy conversion and so in measured in volt ampere VA Reactive. power is measured in volt amperes reactive VAr,TCG Imperial College 1 15.


Related Books

CRYOGENIC ENGINEERING

CRYOGENIC ENGINEERING

Introduction to Cryogenic Systems: Historical development, Applications of Cryogenics (Space, Food Processing, Super conductivity, Electrical Power, Biology, Medicine, Electronics and Cutting Tool Industry). Low Temperature Properties: Properties of Engineering Materials (Mechanical properties, Thermal

ALTIVAR 16 AC Drive Catalog - Steven Engineering

ALTIVAR 16 AC Drive Catalog Steven Engineering

Altivar 16 AC Drive Introduction. Introduction. The Altivar 16 AC drive for three-phase asynchronous squirrel cage motors incorporates the latest technology: - Surface mount technology - 16-bit microprocessor - ASIC circuit - IPM power module With its compact design and conformity to international standards, the Altivar 16 is a global product ...

Introduction to Electrical Engineering - SVBIT

Introduction to Electrical Engineering SVBIT

Guru and Hiziroglu,? Electric Machinery and Transformers, 3rd Edition Hoole and Hoole, A Modern Short Course in Engineering Electromagnetics Jones, Introduction to Optical Fiber Communication Systems Krein, Elements of Power Electronics Kuo, Digital Control Systems, 3rd Edition Lathi, Modern Digital and Analog Communications Systems, 3rd Edition

EN 206 Prof. Doolla EN 206 - Power Electronics and Machines

EN 206 Prof Doolla EN 206 Power Electronics and Machines

Power Devices EN 206 - Power Electronics and Machines Introduction Suryanarayana Doolla Department of Energy Science and Engineering Indian Institute of Technology, Bombay [email protected] . EN 206 2/30 Prof. Doolla Introduction Review of Basic Concepts Switching Power Devices Syllabus Single phase and three phase transformers, autotransformers Characteristics of power semi conductor switches ...

Engineering the Electron-Hole Bilayer Tunneling Field ...

Engineering the Electron Hole Bilayer Tunneling Field

semiconductor device modeling, tunneling, tunneling field effect transistor (TFET) I. INTRODUCTION . N order to reduce the power consumption of modern electronics, the operating voltage needs to be significantly reduced. The electron-hole Bilayer Tunneling Field-Effect Transistor (EH Bilayer TFET) is a new device that concept

Arneson Auction Service EST 1937

Arneson Auction Service EST 1937

212 5 RR locomotive photographs 213 c.1976 Audel Carpenters and Builders Library, 4-vol. set 214 c.1973 Audel Home Workshop; c.1967 Audel Plumbers & Pipe Fitters; c.1976 Audel Carpenters & Builders books 215 c.1971 Audel Automobile Guide 216 c.1927 Audel Practical Electricity; c.1951 Audel Television Service Manual 217 c.1954 Audel Engineers ...

PPC-4001-Joanne 6-20-16 - Fireye

PPC 4001 Joanne 6 20 16 Fireye

1 DESCRIPTION Fireye PPC4000, the newest member of the Nexus family, is a state of the art parallel positioning system for all types of liquid or gaseous fuel fired ...

Basic Properties of LNG - Liquefied Natural Gas

Basic Properties of LNG Liquefied Natural Gas

The propane and butane in LPG have different chemical compositions from methane, the primary hydrocarbon in natural gas and LNG. Propane and butane can be stored and transported as a mixture, or separately. Both are gases at normal room temperature and atmospheric pressure, like methane, readily vaporising. Propane liquefies much

CReaderV+ User's Manual EN - crecorder.com

CReaderV User s Manual EN crecorder com

Use extreme caution when working around the ignition coil, distributor cap, ignition wires and spark plugs. These components create hazardous voltages when the engine is running. Put the transmission in P (for A/T) or N (for M/T) and make sure the parking brake is engaged.

Lift Monitoring & Diagnostics System

Lift Monitoring amp Diagnostics System

LNGS.465213.270-10 RE The present manual is intended for getting to know lift unit ver. 7.2 of Lift Monitoring and Diagnostics System, its characteristics and rules for safe operation (use, transportation,